General specifications |
Display |
Digital/ LCD, max. 2000 digits Display update rate: 2 times / s |
Range switching |
Auto-range |
Maximum conductor diameter for measurement |
ø 32 mm (1.26 in) |
Power supply |
AA-size alkaline battery (LR6) x 2 |
Continuous operating time |
Approx. 35 hours
*With backlight off and Bluetooth off (FT6381). |
Auto power-save function |
Power save state when 5 minutes have elapsed since the last operation |
Operating temperature and humidity |
-10°C (14°F) to 50°C (122°F), 80 % rh or less (non-condensation) |
Storage temperature and humidity |
-20°C (-4°F) to 60°C (140°F), 80 % rh or less (non-condensation, except for the battery) |
Dustproof and waterproof |
IP40 (EN60529) With Jaws Closed |
Maximum rated voltage to earth |
600 VAC measurement category IV (anticipated transient overvoltage 8000 V) |
Dielectric strength |
Between the Case and the Clamp core 7400 Vrms 1 minute |
Maximum input current |
100 A AC continuous, 200 A AC for 2 minutes (50/60 Hz) |
Conductor position effects |
Within ±0.5% rdg. (using the center of the sensor as the reference, in all positions) |
Magnetic field interference |
10 mA or less in an external magnetic field of 400 A/m at 50/60 Hz AC |
Applicable standards |
Safety: EN61010 EMC: EN61326
Wireless (For FT6381 only): FCC Part 15.247, IC RSS-210, EN 300 328, 301 489-1, 301-489-17 |
Dimensions, Mass |
Approx. 73 mm (2.87 in) W × 218 mm (8.58 in) H × 43 mm (1.69) D , Approx 620 g (21.9 oz) |
Accessories |
Carrying Case×1, Resistance Check Loop×1, Strap×1, Instruction Manual×1, Alkaline Battery(LR6)×2 |